SciELO - Scientific Electronic Library Online

 
vol.61 número2SYNTHESIS OF ORGANOPHOSPHORUS COMPLEXES AND STRUCTURAL CHARATERIZATION OF TWO DIMERIC TRIPHENYLPHOSPHINNE COMPLEXES OF MERCURY(II) IONS FROM DIMERIC COMPLEXES OF [4-METHYLBENZOYLMETHYLENETRI-P-TOLYLPHOSPHINE MERCURY(II) HALIDESDEVELOPMENT AND VALIDATION OF SIMPLE, RAPID AND SENSITIVE UV, HPLC AND HPTLC METHODS FOR THE ESTIMATION OF PIRFENIDONE IN TABLET DOSAGE FORM índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Journal of the Chilean Chemical Society

versão On-line ISSN 0717-9707

Resumo

MOHAMMADZADEH, ALI  e  RAMEZANI, MAJID. MODELING AND OPTIMIZATION OF IN SYRINGE MAGNET STIRRING ASSISTED-DISPERSIVE LIQUID-LIQUID MICROEXTRACTION METHOD FOR EXTRACTION OF CADMIUM FROM FOOD SAMPLES BY ARTIFICIAL NEURAL NETWORK AND GENETIC ALGORITHM. J. Chil. Chem. Soc. [online]. 2016, vol.61, n.2, pp.2973-2977. ISSN 0717-9707.  http://dx.doi.org/10.4067/S0717-97072016000200024.

For the first time, artificial neural network (ANN) and genetic algorithm (GA) have been employed to modeling and optimization of in syringe magnet stirring assisted dispersive liquid-liquid microextraction (IS-MSA-DLLME) method for extraction of cadmium from food samples and determined by flame atomic absorption spectrometry. Based on one factor at a time optimization method, the different input variables for modeling were chosen as pH of the solution, extraction volume, stirring rate and extraction time. The ANN techniques fitted a model for extraction of cadmium with 8, 0.9988 and 6.4x10-4 neurons, correlation coefficient and mean standard error (MSE), respectively. By using the GA technique, the optimal conditions were achieved at pH 7, extraction volume at 250 μL, stirring rate of 500 rpm and extraction time of 10 min. Under the optimum conditions, the calibration graph was linear over the range of 0.05 - 1.00 μg L-1 and the limits of detection (LOD) were as small as 0.015 μg mL-1. The relative standard deviation was ±2.11% (n = 7) and the enrichment factor was 280. The developed method was successfully applied to the extraction and determination of cadmium in food samples.

Palavras-chave : Artificial Neural Network; Genetic Algorithm; Cadmium; In Syringe Magnet Stirring Assisted Dispersive Liquid-Liquid Microextraction.

        · texto em Inglês     · Inglês ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons