SciELO - Scientific Electronic Library Online

 
vol.61 número2THE USAGE OF CARROT POMACE FOR BIOETHANOL PRODUCTIONFOUR-DIMENSIONAL INCOMMENSURATELY MODULATED STRUCTURE OF THULIUM POLYPHOSPHATE índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

Links relacionados

  • Em processo de indexaçãoCitado por Google
  • Não possue artigos similaresSimilares em SciELO
  • Em processo de indexaçãoSimilares em Google

Compartilhar


Journal of the Chilean Chemical Society

versão On-line ISSN 0717-9707

Resumo

SHAH, UMANG; GANDHI, AYUSHI  e  DAWAWALA, TRUPTI. REVERSE PHASE HPLC AND DERIVATIVE SPECTROPHOTOMETRIC METHODS FOR SIMULTANEOUS ESTIMATION OF FENBENDAZOLE AND NICLOSAMIDE IN PHARMACEUTICAL DOSAGE FORM. J. Chil. Chem. Soc. [online]. 2016, vol.61, n.2, pp.2999-3004. ISSN 0717-9707.  http://dx.doi.org/10.4067/S0717-97072016000200030.

The present study narrates the developed and validated simple, reliable, sensitive, precise and accurate Spectrophotometric and RP-HPLC methods for the simultaneous estimation of Fenbendazole and Niclosamide in pharmaceutical dosage form. In the first order derivative method 0.1 N methanolic HCl was used as diluent. The zero crossing point wavelengths selected for the analysis were 226 nm and 317 nm for Fenbendazole and Niclosamide, respectively and RP-HPLC method has been developed using 1% methanolic HCl as diluent. Separations of drugs were achieved on L1 C18 100 A° column (250 x 4.6 mm, 5 μ) using 2 gm potassium dihydrogen phosphate and acetonitrile (70:30, v/v) as mobile phase with flow rate 1.0 mL/min. The detection wavelength was 290 nm. Validation of developed methods was done according to ICH Q2 (R1) guideline. Calibration curve was linear over the concentration range of 3-9 μg/mL (Fenbendazole) and 10-30 μg/mL (Niclosamide) for spectrophotometric method and 24-39 μg/mL (Fenbendazole) and 80-130 μg/mL (Niclosamide) for RP-HPLC method. The developed RP-HPLC and derivative spectrophotometric method were successfully applied for the quantitative determination of cited drugs in pharmaceutical dosage form. The correlation coefficients (r2) value greater than 0.995. Accuracy of methods were determined by recovery studies and it was found to be 98 to 102 %. The % RSD values for all the validation parameters were less than 2.0 % for both the methods. The developed UV and RP-HPLC methods were compared by t - test and it was found that tstat value was less than tcritical, value for all. Hence there was no significant difference between the developed methods.

Palavras-chave : Fenbendazole; Niclosamide; UV- Spectrophotometry; RP-HPLC; Validation.

        · texto em Inglês     · Inglês ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons